Engineering drawing abbreviations: TYP, THRU, 4X, REF and more
Reading table
| Abbreviation | Means | What to do in a report |
|---|---|---|
| 4X (or any N X) | The callout applies to that many features | One balloon with N results, or split into sub-numbers |
| TYP | Typical: the same applies to similar features | Confirm how many features it covers; ask if unclear |
| THRU | The hole goes all the way through | Record as part of the requirement; check the feature goes through |
| REF | Reference value, information only | Normally not inspected |
| MAX / MIN | The value is an upper or lower limit | Record the limit; result must not pass it |
| DIA or the diameter sign | Diameter | Part of the requirement text |
| R | Radius | Part of the requirement text |
| SQ | Square | Part of the requirement text |
| CSK / CBORE | Countersink / counterbore | See hole callouts |
| DP | Depth | Part of the requirement text |
What does 4X mean on a drawing?
4X means the callout applies to four features. Example: "4X diameter 9.0 plus or minus 0.1 THRU" is four holes. Record it as one balloon with four results, or split it into 6.1 to 6.4 so each hole has its own result, as the tool does with its split-quantity action.
TYP
TYP means typical. It says one dimension stands for several like features. Inspectors must confirm how many features it covers, because the drawing does not always say.
THRU
THRU means the feature passes entirely through the part. In "diameter 9.0 THRU" there is no depth to measure, but the hole must break out the far side.
Common mistakes
- Measuring one hole when the callout covers four.
- Treating TYP as a count.
More abbreviations, with an example each
The table below goes beyond the first ones. The meanings are common drafting usage, written in our own words: the drawing's own notes and the standard it cites govern, and where an abbreviation could mean two things, ask.
| Abbreviation | Meaning | Example on a drawing | Effect on the report |
|---|---|---|---|
| B.C. | Bolt circle: the circle on which a hole pattern lies | 90.0 B.C. | One characteristic for the circle diameter; the holes are separate |
| BSC or BASIC | Basic size, a theoretically exact value | 25.00 BSC | No plus-minus; judge the governing frame |
| REF | Reference value, for information | 50.0 REF | Normally not balloon-worthy |
| TYP | Typical: applies to similar features | R3 TYP | Confirm the count of features |
| EQ SP | Equally spaced | 6X EQ SP | Spacing is part of the requirement |
| 4X, 6X | Quantity prefix | 4X 9.0 THRU | One balloon, several results |
| THRU | Passes completely through | 9.0 THRU | Check it breaks through |
| DP | Depth | 6 DP | A separate measurement |
| CBORE | Counterbore | CBORE 11 DP 6.5 | Diameter and depth |
| CSK | Countersink | CSK 90 deg | Diameter and angle |
| SQ | Square | SQ 12 | Both sides |
| DIA | Diameter, written out | DIA 30 | Same as the diameter symbol |
| R | Radius | R3 | Check with a radius gauge |
| MAX, MIN | Upper or lower limit | 0.8 MAX | One-sided limit; result must not pass it |
| NTS | Not to scale | NTS under a view | Do not scale from it |
| SF or Ra | Surface finish | Ra 1.6 | Profilometer reading |
| C/L | Centre line | C/L | Reference for symmetry |
| MMC, LMC | Maximum, least material condition | circled M | Bonus tolerance may apply |
| UNO | Unless otherwise specified | UNO 0.5 R | Applies where nothing else is stated |
| ALL OVER | Applies to every surface | 0.4 ALL OVER | One note, many surfaces |
Worked example on the sample part
The sample's hole callout is 4X diameter 9.0 plus or minus 0.1 THRU. Reading the abbreviations: 4X gives four holes, THRU says each passes right through. The tool balloons it once, as balloon 6, with limits 8.9 to 9.1. With split quantity turned on it becomes 6.1 to 6.4, one result per hole. The bolt circle callout 90.0 B.C. is balloon 7, and it is a separate characteristic from the holes.
Reading a callout from left to right
A line such as "4X diameter 9.0 plus or minus 0.1 THRU" reads: quantity, symbol, size, tolerance, instruction. Each piece answers a question. How many, what shape, how big, how accurate, how deep. When a callout adds a counterbore, repeat the same questions for it.
Mistakes inspectors make
- Counting TYP features from the view the callout is in, and missing identical features in other views. Confirm with the drawing owner.
- Treating B.C. as a tolerance and not a location.
- Measuring a MAX value as if it were a nominal with a plus-minus.
- Reading EQ SP as optional: equally spaced is a requirement, and the spacing needs a result.
- What does 4X mean on a drawing?
- The callout applies to four features.
- What does TYP mean on an engineering drawing?
- Typical: the same applies to similar features. Confirm how many.
- What does THRU mean on a drawing?
- The hole passes all the way through.
- How do I record a 4X dimension?
- See the 4X section above.
- What does B.C. mean on an engineering drawing?
- B.C. means bolt circle, the circle on which a pattern of holes lies. The diameter printed with it is the diameter of that circle, and it is a separate characteristic from the hole sizes. Measure and record both, as separate balloons.
- What does UNO mean on a drawing?
- UNO means unless otherwise specified. A note such as UNO 0.5 R says every radius takes that value except where the drawing gives another. Treat it as a requirement for each such feature, and balloon those features that carry no value of their own.
Related
- Hole callouts: counterbore, countersink, depth and diameter symbols
- How to read an engineering drawing as a machinist or inspector
- How to balloon a drawing: a step-by-step method for inspection reports
- Reference dimension: definition, brackets and whether to inspect it
- Open the tool and try it on a drawing