The Form 3-style inspection report, column by column

Last reviewed 19 November 2026 · Written by Paul, who also builds and supports the tool

A Form 3-style report is a table with a header strip and one row per ballooned characteristic. Each row says which characteristic it is, where it is on the drawing, what is required, what was measured, what was measured with, and whether anything was out. The layout below is ours, written from public customer forms, and is not the official form.
Detail A · The header strip

Who and what the report is about

Above the table sit the identifying fields: the part number and name, the serial or lot number, a report identifier, the drawing revision, who prepared it and the date. In the tool these are in Report header and are all optional, so you can export with blanks and fill them later.

Detail B · The columns

What each column means

Column What goes in it
No. The balloon number, such as 7 or 6.2. One row per number.
Sheet and zone The sheet of the drawing and, if it has one, the grid zone where the feature sits, so the reader can find it.
Designator An optional note such as a key characteristic marking, if your customer uses one.
Requirement What the drawing says, as printed: a size and tolerance, a note, or a feature control frame.
Min and Max The limits worked out from the requirement. The tool computes them in exact decimals.
Result What you measured. One column per measured part if you measure several.
Verdict In or out of tolerance, always in words, because reports get photocopied in greyscale.
Tooling The gauge, micrometer or machine used.
Notes A nonconformance reference or any explanation.

A worked example

Here is the sample part from the ballooning guide, as the tool reports it.

Report rows for the sample drawing
No.RequirementMinMaxResultVerdict
120.0 ±0.219.820.220.08IN TOL
270.0 ±0.369.770.369.91IN TOL
3⌀110.0 ±0.1109.9110.1110.04IN TOL
4⌀70.0 +0.03/070.070.0370.02IN TOL
5⌀30.00 +0.02/030.0030.0230.01IN TOL
64X ⌀9.0 ±0.1 THRU8.99.19.05IN TOL
7⌀90.0 ±0.1 B.C.89.990.190.03IN TOL

Table: rows produced by the tool for the sample drawing. The measured results are made-up demo values.

Read row 4 as an example of an asymmetric tolerance: the diameter is 70.0 with a tolerance of plus 0.03 and nothing below, so the limits run from 70.0 up to 70.03. A result of 70.02 is inside.

Detail C · Things readers check first

Mistakes that get a report sent back

  • A verdict with no limits. If you cannot say what the limits were, the verdict is not checkable.
  • Results to a different precision than the drawing. If the tolerance is in hundredths, record hundredths.
  • Missing tooling. A reader wants to know the measurement was made with something fit for the tolerance.
  • No note against an out-of-tolerance row. Every out-of-tolerance row needs a note saying what was done.

Get a blank copy

The free template generator makes a blank report in this layout as PDF or Excel. The first article inspection report template page explains how to fill it from a drawing.

Questions from practitioners

What if the drawing itself has an error? Do not correct it on the report. Record the characteristic as printed, note the discrepancy, and raise it with the drawing owner. A report that silently fixes the drawing cannot be traced to it.

How do I enter attribute checks? For a check with no number, such as a thread gauge or a visual inspection, write the requirement as the drawing states it and record the result as accept or reject, with the gauge in the tooling column. The tool shows no verdict for such rows, which is correct: there are no limits to compare.

What about notes and material callouts? A note that calls for something to be checked, such as a coating, a hardness or a marking, is a characteristic. Give it a balloon and a row.

What goes in the result for a 4X feature? One balloon with four results, or four sub-numbered rows. Ask which the customer prefers.

What goes in the reference-location column? The sheet and the zone where the characteristic sits, so a reader can find it on the print.

A column-by-column check of the sample

Column Sample row 4 Check
Characteristic number 4 Matches balloon 4 on the drawing
Requirement diameter 70.0 plus 0.03 over 0 Copied as printed
Min / Max 70.0 / 70.03 Nominal plus the lower and upper tolerances
Result 70.02 Same decimals as the limits
Verdict In tolerance 70.02 is not below 70.0 or above 70.03

Doing this check on three or four rows is the quickest way to see whether a report was built carefully.

Is this the official form?
No. It is our own table laid out in the same arrangement. Column headings are short labels we wrote, and nothing from the standard is reproduced. This site is not affiliated with or endorsed by SAE International.
Can I add columns?
In the tool you can add measured-part columns. For anything else, edit the Excel export.
How do I fill out an AS9102 Form 3?
Fill the header, then one row per ballooned characteristic: number, location, requirement, results, tooling and any nonconformance reference. Our Form 3-style layout follows that arrangement and is not the official form.
What goes in the reference location column?
The sheet and the zone where the characteristic sits on the drawing, so a reader can find it on the print.
How do I enter attribute checks such as a thread gauge?
Write the requirement as printed, record accept or reject as the result and name the gauge in the tooling column. There are no numeric limits, so the tool shows no verdict.
What do I do if the drawing has an error?
Record the characteristic as printed, note the discrepancy and raise it with the drawing owner. Do not correct the drawing silently on the report.

Open a drawing — free

Related

Do not scale drawingThird-angle projectionSheet 1 of 1balloonmydrawing.com
Built and supported by Paul: [email protected]. AS9102 is a standard of SAE International; this site is not affiliated with or endorsed by SAE. Nothing here reproduces the standard. Explanations are our own and are not legal or compliance advice.Privacy · Terms · Refunds