The Form 3-style inspection report, column by column
Who and what the report is about
Above the table sit the identifying fields: the part number and name, the serial or lot number, a report identifier, the drawing revision, who prepared it and the date. In the tool these are in Report header and are all optional, so you can export with blanks and fill them later.
What each column means
| Column | What goes in it |
|---|---|
| No. | The balloon number, such as 7 or 6.2. One row per number. |
| Sheet and zone | The sheet of the drawing and, if it has one, the grid zone where the feature sits, so the reader can find it. |
| Designator | An optional note such as a key characteristic marking, if your customer uses one. |
| Requirement | What the drawing says, as printed: a size and tolerance, a note, or a feature control frame. |
| Min and Max | The limits worked out from the requirement. The tool computes them in exact decimals. |
| Result | What you measured. One column per measured part if you measure several. |
| Verdict | In or out of tolerance, always in words, because reports get photocopied in greyscale. |
| Tooling | The gauge, micrometer or machine used. |
| Notes | A nonconformance reference or any explanation. |
A worked example
Here is the sample part from the ballooning guide, as the tool reports it.
| No. | Requirement | Min | Max | Result | Verdict |
|---|---|---|---|---|---|
| 1 | 20.0 ±0.2 | 19.8 | 20.2 | 20.08 | IN TOL |
| 2 | 70.0 ±0.3 | 69.7 | 70.3 | 69.91 | IN TOL |
| 3 | ⌀110.0 ±0.1 | 109.9 | 110.1 | 110.04 | IN TOL |
| 4 | ⌀70.0 +0.03/0 | 70.0 | 70.03 | 70.02 | IN TOL |
| 5 | ⌀30.00 +0.02/0 | 30.00 | 30.02 | 30.01 | IN TOL |
| 6 | 4X ⌀9.0 ±0.1 THRU | 8.9 | 9.1 | 9.05 | IN TOL |
| 7 | ⌀90.0 ±0.1 B.C. | 89.9 | 90.1 | 90.03 | IN TOL |
Read row 4 as an example of an asymmetric tolerance: the diameter is 70.0 with a tolerance of plus 0.03 and nothing below, so the limits run from 70.0 up to 70.03. A result of 70.02 is inside.
Mistakes that get a report sent back
- A verdict with no limits. If you cannot say what the limits were, the verdict is not checkable.
- Results to a different precision than the drawing. If the tolerance is in hundredths, record hundredths.
- Missing tooling. A reader wants to know the measurement was made with something fit for the tolerance.
- No note against an out-of-tolerance row. Every out-of-tolerance row needs a note saying what was done.
Get a blank copy
The free template generator makes a blank report in this layout as PDF or Excel. The first article inspection report template page explains how to fill it from a drawing.
Questions from practitioners
What if the drawing itself has an error? Do not correct it on the report. Record the characteristic as printed, note the discrepancy, and raise it with the drawing owner. A report that silently fixes the drawing cannot be traced to it.
How do I enter attribute checks? For a check with no number, such as a thread gauge or a visual inspection, write the requirement as the drawing states it and record the result as accept or reject, with the gauge in the tooling column. The tool shows no verdict for such rows, which is correct: there are no limits to compare.
What about notes and material callouts? A note that calls for something to be checked, such as a coating, a hardness or a marking, is a characteristic. Give it a balloon and a row.
What goes in the result for a 4X feature? One balloon with four results, or four sub-numbered rows. Ask which the customer prefers.
What goes in the reference-location column? The sheet and the zone where the characteristic sits, so a reader can find it on the print.
A column-by-column check of the sample
| Column | Sample row 4 | Check |
|---|---|---|
| Characteristic number | 4 | Matches balloon 4 on the drawing |
| Requirement | diameter 70.0 plus 0.03 over 0 | Copied as printed |
| Min / Max | 70.0 / 70.03 | Nominal plus the lower and upper tolerances |
| Result | 70.02 | Same decimals as the limits |
| Verdict | In tolerance | 70.02 is not below 70.0 or above 70.03 |
Doing this check on three or four rows is the quickest way to see whether a report was built carefully.
- Is this the official form?
- No. It is our own table laid out in the same arrangement. Column headings are short labels we wrote, and nothing from the standard is reproduced. This site is not affiliated with or endorsed by SAE International.
- Can I add columns?
- In the tool you can add measured-part columns. For anything else, edit the Excel export.
- How do I fill out an AS9102 Form 3?
- Fill the header, then one row per ballooned characteristic: number, location, requirement, results, tooling and any nonconformance reference. Our Form 3-style layout follows that arrangement and is not the official form.
- What goes in the reference location column?
- The sheet and the zone where the characteristic sits on the drawing, so a reader can find it on the print.
- How do I enter attribute checks such as a thread gauge?
- Write the requirement as printed, record accept or reject as the result and name the gauge in the tooling column. There are no numeric limits, so the tool shows no verdict.
- What do I do if the drawing has an error?
- Record the characteristic as printed, note the discrepancy and raise it with the drawing owner. Do not correct the drawing silently on the report.