Dimensional inspection report template: Excel and PDF, free blank

Last reviewed 19 November 2026 · Written by Paul, who also builds and supports the tool

A dimensional inspection report lists every dimension of a part, its tolerance limits and the measured value, with a pass or fail against each. The blank template below has those columns as PDF and Excel, built in your browser.
Detail A · Columns

What goes in the table

Column Meaning
No. The balloon number on the drawing
Requirement The dimension as printed
Min and Max The limits worked out from the tolerance
Result What was measured
Verdict In or out, in words
Tooling The instrument used
Notes A reason for any out-of-tolerance result
Detail B · Get the template

Download

TemplatePDFExcel
Form 1-style: part identification sheet
Form 2-style: materials, processes and tests list
Form 3-style: characteristic report

Generated in your browser by the same exporter the tool uses. Nothing is uploaded.

For a filled example, see the worked report.

FLANGED BUSHING - SAMPLE PARTDRAWN FOR balloonmydrawing.com SHEET 1 OF 1 MMSECTION A-AFRONT VIEW20.0 ±0.270.0 ±0.3⌀110.0 ±0.1⌀70.0 +0.03/0⌀30.00 +0.02/04X ⌀9.0 ±0.1 THRU⌀90.0 ±0.1 B.C.1234567
Figure 1. Balloons on a drawing become the numbered rows of the report.

Common mistakes

  • Recording a result without its tooling.
  • Mixing units between rows.

Using the template well

Print it on one landscape page for a short part, or use the Excel version for a long one. Fill the Requirement column from the drawing exactly as printed, including the tolerance, so a reader can check the limits against the print. Work out Min and Max once, and then record each result to the same number of decimal places as the tolerance.

A short worked row

Requirement: 20.0 plus or minus 0.2. Min 19.8, Max 20.2. Result 20.1. Verdict: within tolerance. Tooling: caliper. Notes: blank. The same row with a result of 20.3 would carry the verdict out of tolerance by 0.1 and a note saying what was done about it.

When to use something else

If the customer supplies their own report form, use theirs. If your job needs the three-form arrangement, use the Forms 1, 2 and 3 page. If you want the table built from the drawing instead of typed, use the tool.

Mistakes to avoid

  • Typing limits by hand and miscalculating them. Let the tool work them out, or check each one.
  • Leaving verdicts blank on in-tolerance rows. Blank is ambiguous.
  • Recording results to more places than the instrument can resolve.

Worked example from the sample part

The sample drawing's seven characteristics fill the template like this. The limits come from the tolerances as printed, and the results are demonstration values.

Report rows for the sample drawing
No.RequirementMinMaxResultVerdict
120.0 ±0.219.820.220.08IN TOL
270.0 ±0.369.770.369.91IN TOL
3⌀110.0 ±0.1109.9110.1110.04IN TOL
4⌀70.0 +0.03/070.070.0370.02IN TOL
5⌀30.00 +0.02/030.0030.0230.01IN TOL
64X ⌀9.0 ±0.1 THRU8.99.19.05IN TOL
7⌀90.0 ±0.1 B.C.89.990.190.03IN TOL

Table: rows produced by the tool for the sample drawing. The measured results are made-up demo values.

Row 4, diameter 70.0 with plus 0.03 and nothing below, has limits 70.0 and 70.03 and a demonstration result of 70.02, so it is in tolerance with 0.01 to spare. Row 6, the 4X hole callout, has limits 8.9 to 9.1 and could be split into 6.1 to 6.4 if each hole needs its own result.

Field by field

Field How to fill it
Part number, revision, date From the drawing's title block and today's date
No. The balloon number; use sub-numbers for split quantities
Requirement Copy the dimension as printed, including its tolerance and any 4X
Min and Max Work out once: nominal plus the lower tolerance and nominal plus the upper
Result The reading as the instrument gave it, to the same decimals as the tolerance
Verdict In or out, in words, never a colour only
Tooling The instrument and, if your system asks, its identifier
Notes For any out-of-tolerance result, what was found and what happened next

Choosing between PDF and Excel

Use the PDF for a printed or emailed record and the Excel file when a reviewer will sort, filter or import the rows. Both come from the same table, so they cannot disagree. If you build the report from a drawing in the tool, the Excel export also carries the limits as numbers rather than text.

Mistakes people make

  • Writing a verdict before comparing against limits, usually on the last few rows of a long list.
  • Recording results to more decimals than the instrument can resolve, which implies a precision that does not exist.
  • Mixing inches and millimetres in one table without a note.
  • Leaving the revision blank so the report cannot be tied to a drawing issue.
Is it only for aerospace?
No. Any shop reporting dimensions to a drawing can use it.
What is a dimensional inspection report?
A dimensional inspection report lists the dimensions of a part with their tolerance limits and the measured value for each, with a pass or fail against every one. It is the core of a first article report and of PPAP dimensional results.
What should a dimensional inspection report include?
A header that identifies the part, drawing and revision, one numbered row per characteristic with the requirement, limits, result, verdict and tooling, and a note against every out-of-tolerance row. Our template has all of these columns.
Is there a dimensional inspection report template in Excel?
Yes. The template on this page downloads as Excel as well as PDF, generated in your browser, and the Excel version keeps the headings in a frozen header row.

Open a drawing — free

Related

Do not scale drawingThird-angle projectionSheet 1 of 1balloonmydrawing.com
Built and supported by Paul: [email protected]. AS9102 is a standard of SAE International; this site is not affiliated with or endorsed by SAE. Nothing here reproduces the standard. Explanations are our own and are not legal or compliance advice.Privacy · Terms · Refunds