Feature control frame: how to read it, with three worked readings
Left to right
- Symbol: which characteristic (position, flatness, perpendicularity and so on).
- Tolerance: the width of the zone. A diameter sign in front means a cylindrical zone.
- Modifier, if present: M (maximum material), L (least material).
- Datums: up to three letters, primary first, then secondary, then tertiary.
Worked examples
| Frame | Reading |
|---|---|
| Position, diameter 0.30, A, B | The axis must lie within a 0.30 cylinder located from datums A then B |
| Flatness 0.05 | The surface must lie between two parallel planes 0.05 apart. No datum needed |
| Perpendicularity 0.10, A | The feature must lie between two planes 0.10 apart, perpendicular to datum A |
Worked example: three frames with generated text
The tool writes frames as text. A position frame with a diameter zone prints as shown by the position page, and a flatness frame has no datum. Each of these is generated by the tool's own code, so what you read on the other characteristic pages matches what appears in your report. For the sample bushing, which carries no frames, the corresponding rows would hold only a size requirement; a frame would add a separate characteristic row.
How to enter one in a report
In the tool, open the GD&T builder, pick the symbol, enter the tolerance, modifier and datums, and the requirement column is filled with the frame text. See the symbol chart.
Common mistakes
- Ignoring the order of datums.
- Missing the diameter sign, which changes the zone shape.
- Reading a basic dimension as if it had a plus-or-minus.
The pieces in more detail
The symbol compartment. The first compartment holds one of the fourteen geometric characteristic symbols. The symbol tells you which kind of control it is: form (flatness, straightness, circularity, cylindricity), orientation (parallelism, perpendicularity, angularity), location (position, concentricity, symmetry), runout, or profile.
The tolerance compartment. The number is the width of the tolerance zone. If a diameter sign sits in front, the zone is a cylinder or circle of that diameter. Without it, the zone is the space between two parallel lines or planes that far apart. This is a common reason for a wrong reading.
The datum compartments. Form controls have none. Others have one, two or three, from left to right in priority order.
Above and below the frame
Text above the frame, such as 4X, says how many features it covers. A note beneath, such as a datum feature symbol, links to the surface. A frame may also be attached to a dimension, which is a way of saying that it applies to the feature of size.
Why this matters for a report
The frame is the requirement. When you balloon it, copy the complete text into the Requirement column so a reader can see the symbol, zone and datums. Then record a single result: the measured value of the characteristic, compared with the tolerance.
- How do you read a feature control frame?
- Left to right: symbol, tolerance (with any modifier), then datums in order.
- How do I enter a GD&T callout in an inspection report?
- Use the GD&T builder, or write the frame as text in the Requirement column.
- What are the parts of a feature control frame?
- A symbol compartment, a tolerance compartment with an optional diameter sign and modifier, and up to three datum compartments in priority order.
- What does the diameter sign in a frame mean?
- It says the tolerance zone is a cylinder or circle of that diameter, not the space between two parallel lines or planes.
Related
- GD&T symbols reference: the fourteen characteristics explained
- Position in GD&T
- Datums in GD&T: what they are, how they are labelled and how to read them
- Maximum and least material condition (MMC, LMC): definition and bonus tolerance
- Basic dimension: definition, the box, and how to report it
- Open the tool and try it on a drawing