Inspection plan from a drawing: how to build one, and the control plan difference

Last reviewed 19 November 2026 · Written by Paul, who also builds and supports the tool

An inspection plan says what will be measured on a part, with what instrument and how often. A control plan covers the whole process: it lists process steps, the characteristics controlled at each and the reaction if something drifts. In short, an inspection plan is about checking the part; a control plan is about controlling the process.
Detail A · Comparison

Inspection plan and control plan

Inspection plan Control plan
Focus The part and its characteristics The process that makes it
Lists Characteristic, instrument, frequency, record Process step, characteristic, method, reaction plan
Built from The ballooned drawing Process flow and risk analysis
Detail B · Build one

Steps

  1. Balloon the drawing so every characteristic has a number.
  2. For each, choose an instrument that resolves a tenth of the tolerance or better, if your system uses that rule of thumb.
  3. Set a frequency: first article, then per lot or per hour as your customer and system require.
  4. Say where the result is recorded.
  5. Export the table from the tool as the starting point.

Common mistakes

  • Choosing an instrument too coarse for the tolerance.
  • Writing a plan that is never used on the shop floor.

A worked fragment

For the sample part, the plan for a 70.0 plus 0.03 and zero diameter might read: characteristic 4, diameter 70.0 plus 0.03 / minus 0, instrument a micrometer or bore gauge resolving 0.001, frequency first article and then one in ten, record in the report. For the 20.0 plus or minus 0.2 length, a caliper reading to 0.01 is plenty, and the plan can say so. Matching instrument to tolerance is the real content of an inspection plan.

Choosing frequency

First article is every characteristic once. After that, frequency depends on the risk: a tight tolerance, a feature that the process drifts on, or a customer requirement calls for more checks. Write the reason next to the frequency, so the person who inherits the plan can tell what may safely be relaxed.

Where the control plan comes in

A control plan sits above the inspection plan. It names the operation in which a characteristic is created, what is controlled at that operation, how it is measured, and what to do when it drifts. Your inspection plan supplies the measurement row for each characteristic. Customers who ask for a control plan will usually say which format they expect.

Mistakes to avoid

  • Planning every characteristic at the same frequency regardless of risk.
  • Listing an instrument the shop does not own.
  • Copying a plan from another part without checking the tolerances.

Worked example: a plan for the sample part

No. Characteristic Instrument Frequency Record
1 20.0 plus or minus 0.2 Caliper, 0.01 First article, then 1 in 10 Report row 1
3 Diameter 110.0 plus or minus 0.1 Micrometer or caliper, per your gauge study First article, then 1 in 10 Report row 3
4 Diameter 70.0, plus 0.03 over 0 Micrometer or bore gauge, 0.001 Every part Report row 4
5 Diameter 30.00, plus 0.02 over 0 Micrometer or bore gauge, 0.001 Every part Report row 5
6 4X diameter 9.0 plus or minus 0.1 THRU Pin gauge set First article, then 1 in 10 Report row 6, four results

The frequencies are illustrations of a risk-based plan, not recommendations: tighter tolerances get more checks. Rows 2 and 7 would follow the same pattern. The tolerance on row 4 is 0.03 wide, so an instrument that resolves 0.001 is about right, and one resolving 0.01 cannot show the verdict.

Choosing an instrument

A common shop rule of thumb is that the instrument should resolve about a tenth of the tolerance width. It is a rule of thumb, not a universal requirement, and your customer or quality system may set its own. For row 4, a tenth of 0.03 is 0.003, which a 0.001 micrometer meets and a 0.01 caliper does not.

Where the plan lives

An inspection plan is a working document: it hangs by the machine or sits in the quality system. A control plan is a controlled document owned by quality engineering. If your customer asks for a control plan, they will give the format. Do not try to deliver one from this plan alone.

Mistakes people make

  • Plans that list every characteristic at the same frequency regardless of risk.
  • Instruments listed that the shop does not own.
  • Plans never updated after a drawing revision.
  • Confusing the plan with the report: the plan says what will be done, the report says what was found.
Is a ten-to-one rule required?
It is a common rule of thumb, not a universal requirement.
What is the difference between an inspection plan and a control plan?
An inspection plan lists what will be measured on a part, with what instrument and how often. A control plan covers the whole process: where each characteristic is created, how it is controlled and what to do when it drifts.
How do I make an inspection plan from a drawing?
Balloon the drawing so every characteristic has a number, then for each one choose an instrument that resolves the tolerance, set a frequency and name where the result is recorded.
What should an inspection plan include?
The characteristic number and requirement, the instrument, the frequency, the record location and any reaction if a result fails. Add the drawing revision so the plan can be tied to a version.
How often should I inspect each characteristic?
It depends on the risk and the customer's terms: first article for all, then more often for tight or drifting features. Write down why each frequency was chosen.

Open a drawing — free

Related

Do not scale drawingThird-angle projectionSheet 1 of 1balloonmydrawing.com
Built and supported by Paul: [email protected]. AS9102 is a standard of SAE International; this site is not affiliated with or endorsed by SAE. Nothing here reproduces the standard. Explanations are our own and are not legal or compliance advice.Privacy · Terms · Refunds