Total runout in GD&T

Last reviewed 19 November 2026 · Written by Paul, who also builds and supports the tool

Total runout limits the variation over an entire surface as the part turns about a datum axis.

Detail A · What it controls

What Total runout controls

Total runout is the strict relative of circular runout. The indicator travels along the whole surface while the part rotates, and the reading across everything must stay within the tolerance. On a cylinder it controls roundness, straightness and taper together relative to the datum axis; on a face it controls how much the face wobbles.

Tolerance zone. The tolerance is the total indicator movement over the entire surface, not at single slices. The indicator is moved along the surface during rotation.

Detail B · How an inspector checks it

How Total runout is inspected

Set the part on the datum axis, put an indicator against the surface and move it along the length, or across the face, while the part turns. Read the largest and smallest values seen over the whole run, and take the difference. A coordinate measuring machine with scanning can calculate it from many scanned points.

How to measure Total runout

Total runout is measured with the instruments below; the table says how each is set up and what you write down.

Instrument Set-up What is recorded
Dial indicator on centres Part turned while the indicator moves along the surface Indicator range over the whole surface
CMM Points on the whole surface about the datum axis Combined deviation

Total runout compared with Circular runout

Commonly confused with The difference
Circular runout Total runout covers the whole length; circular runout covers one position.
Detail C · Entering it in the tool

How to enter Total runout in the tool

In the characteristic table, press GD&T on the row, choose the Total runout symbol, type the tolerance and choose the datum letters in the order the frame prints them. The tool writes the frame into the Requirement column as text, and the report prints it. For example, a frame with a tolerance of 0.1 is written as ⌰ | 0.1 | A on screen and as TRUN | 0.1 | A in the PDF report, where the standard PDF fonts have no GD&T glyphs.

Datum reference: Yes. It is always measured about a datum axis.

Worked example: reading and judging a Total runout frame

The bundled sample drawing has no feature control frames, so this example uses an invented frame, written by the tool as ⌰ | 0.1 | A. The tolerance is 0.1, which gives a zone 0.1 wide. The inspector measures the feature and finds a Total runout error of 0.08. That is less than 0.1, so the feature is in tolerance with room to spare. A second part measures 0.12. That is more than 0.1, so it is out of tolerance by 0.02. The report row for the second part carries the frame text as the requirement, 0.12 as the result, a verdict in words and a note saying what happened to the part.

Measured Total runout Tolerance Verdict
0.08 0.1 In tolerance
0.12 0.1 Out of tolerance

The numbers are generated from the example the tool itself uses for this symbol, so they stay in step with the frame text shown above. Both are illustrations, not data from a real part.

Detail D · Common mistakes

Mistakes to avoid with Total runout

Using the single-slice reading from circular runout. Total runout needs the indicator to travel, so one position is not enough. Also take care with a long part: sag between supports adds to the reading, so support it as the datum is defined.

Does Total runout need a datum?
Yes. It is always measured about a datum axis.
Which group of controls is Total runout in?
It is a Runout control. The groups are form, profile, orientation, location and runout, and they differ in what they relate the feature to.
How do you measure Total runout?
One common method is the Dial indicator on centres: Part turned while the indicator moves along the surface, and the inspector records: Indicator range over the whole surface. The method table on this page lists the alternatives and what each records.
What is Total runout commonly confused with?
Circular runout. Total runout covers the whole length; circular runout covers one position.
How do I enter Total runout in an inspection report?
Press GD&T on the row in the characteristic table, pick the symbol, type the tolerance and any modifier or datums. The tool writes the frame into the Requirement column as text, and the report prints it.

Open a drawing — free

Related

Do not scale drawingThird-angle projectionSheet 1 of 1balloonmydrawing.com
Built and supported by Paul: [email protected]. AS9102 is a standard of SAE International; this site is not affiliated with or endorsed by SAE. Nothing here reproduces the standard. Explanations are our own and are not legal or compliance advice.Privacy · Terms · Refunds