Perpendicularity in GD&T
What Perpendicularity controls
Perpendicularity controls the ninety-degree relationship between a feature and a datum. It is an orientation control: it fixes the tilt and also limits the form of a surface, but it does not control where along the datum the feature is placed.
Tolerance zone. For a face, the zone is two parallel planes a tolerance value apart, perpendicular to the datum. For a hole or pin axis with a diameter sign, the zone is a cylinder of that diameter standing perpendicular to the datum plane.
How Perpendicularity is inspected
Set the datum surface on a surface plate, then use a square and indicator, or an indicator on a height stand, to read the feature across its length; the spread is the error. For an axis, a coordinate measuring machine fits the axis and reports the cylinder it fits inside. A gauge pin in the hole against a plate is a quick functional check for a hole.
How to measure Perpendicularity
Perpendicularity is measured with the instruments below; the table says how each is set up and what you write down.
| Instrument | Set-up | What is recorded |
|---|---|---|
| Square and indicator | Datum on a plate, indicator across the surface or along the axis | Indicator range |
| CMM | Datum plane and the feature measured, deviation from 90 degrees derived | Zone width the feature occupies |
Perpendicularity compared with Angularity
| Commonly confused with | The difference |
|---|---|
| Angularity | Perpendicularity is the 90 degree case; angularity covers other angles. |
How to enter Perpendicularity in the tool
In the characteristic table, press GD&T on the row, choose the Perpendicularity symbol, type the tolerance, tick Diameter zone, pick the material modifier shown on the drawing and choose the datum letters in the order the frame prints them. The tool writes the frame into the Requirement column as text, and the report prints it. For example, a frame with a tolerance of 0.05 is written as ⟂ | Ø0.05 Ⓜ | A on screen and as PERP | Ø0.05 (M) | A in the PDF report, where the standard PDF fonts have no GD&T glyphs.
Datum reference: Yes. The datum is the surface or axis the feature must stay square to.
Worked example: reading and judging a Perpendicularity frame
The bundled sample drawing has no feature control frames, so this example uses an invented frame, written by the tool as ⟂ | Ø0.05 Ⓜ | A. The tolerance is 0.05, which gives a cylindrical zone 0.05 across. The inspector measures the feature and finds a Perpendicularity error of 0.040. That is less than 0.05, so the feature is in tolerance with room to spare. A second part measures 0.060. That is more than 0.05, so it is out of tolerance by 0.010. The report row for the second part carries the frame text as the requirement, 0.060 as the result, a verdict in words and a note saying what happened to the part.
| Measured Perpendicularity | Tolerance | Verdict |
|---|---|---|
| 0.040 | 0.05 | In tolerance |
| 0.060 | 0.05 | Out of tolerance |
The numbers are generated from the example the tool itself uses for this symbol, so they stay in step with the frame text shown above. Both are illustrations, not data from a real part.
Mistakes to avoid with Perpendicularity
Using a try-square by eye on a tight tolerance, which hides small errors. Another is forgetting the modifier: a maximum material condition on the frame allows extra tolerance as the feature moves away from its maximum size, so the allowed error depends on the measured size.
- Does Perpendicularity need a datum?
- Yes. The datum is the surface or axis the feature must stay square to.
- Which group of controls is Perpendicularity in?
- It is a Orientation control. The groups are form, profile, orientation, location and runout, and they differ in what they relate the feature to.
- How do you measure Perpendicularity?
- One common method is the Square and indicator: Datum on a plate, indicator across the surface or along the axis, and the inspector records: Indicator range. The method table on this page lists the alternatives and what each records.
- What is Perpendicularity commonly confused with?
- Angularity. Perpendicularity is the 90 degree case; angularity covers other angles.
- How do I enter Perpendicularity in an inspection report?
- Press GD&T on the row in the characteristic table, pick the symbol, type the tolerance and any modifier or datums. The tool writes the frame into the Requirement column as text, and the report prints it.