Angularity in GD&T

Last reviewed 19 November 2026 · Written by Paul, who also builds and supports the tool

Angularity limits how far a surface or axis may depart from a stated angle to a datum.

Detail A · What it controls

What Angularity controls

Angularity controls orientation at an angle other than ninety degrees. The feature must stay within a zone that is tilted at the basic angle shown on the drawing relative to a datum. It controls tilt and also form of the surface, but not where the feature sits.

Tolerance zone. For a surface, the zone is the space between two parallel planes a tolerance value apart, set at the basic angle to the datum. For an axis with a diameter sign it is a cylinder at that angle.

Detail B · How an inspector checks it

How Angularity is inspected

On a surface plate, rest the datum surface on a sine bar or an adjustable angle block set to the basic angle, then sweep an indicator over the feature and read the spread. A coordinate measuring machine measures the feature and the datum and reports the angle error converted to the zone width.

How to measure Angularity

Angularity is measured with the instruments below; the table says how each is set up and what you write down.

Instrument Set-up What is recorded
Sine bar and dial indicator Part set at the basic angle on the bar, indicator across the surface Indicator range
CMM Points on the surface and on the datum, angle derived Zone width the surface occupies

Angularity compared with Perpendicularity

Commonly confused with The difference
Perpendicularity Angularity is for any angle other than 90 degrees; perpendicularity is the 90 degree case.
Detail C · Entering it in the tool

How to enter Angularity in the tool

In the characteristic table, press GD&T on the row, choose the Angularity symbol, type the tolerance and choose the datum letters in the order the frame prints them. The tool writes the frame into the Requirement column as text, and the report prints it. For example, a frame with a tolerance of 0.1 is written as ∠ | 0.1 | A on screen and as ANG | 0.1 | A in the PDF report, where the standard PDF fonts have no GD&T glyphs.

Datum reference: Yes. Angularity relates the feature to a datum, so at least one datum reference is needed.

Worked example: reading and judging a Angularity frame

The bundled sample drawing has no feature control frames, so this example uses an invented frame, written by the tool as ∠ | 0.1 | A. The tolerance is 0.1, which gives a zone 0.1 wide. The inspector measures the feature and finds a Angularity error of 0.08. That is less than 0.1, so the feature is in tolerance with room to spare. A second part measures 0.12. That is more than 0.1, so it is out of tolerance by 0.02. The report row for the second part carries the frame text as the requirement, 0.12 as the result, a verdict in words and a note saying what happened to the part.

Measured Angularity Tolerance Verdict
0.08 0.1 In tolerance
0.12 0.1 Out of tolerance

The numbers are generated from the example the tool itself uses for this symbol, so they stay in step with the frame text shown above. Both are illustrations, not data from a real part.

Detail D · Common mistakes

Mistakes to avoid with Angularity

Reading a general angular tolerance in the title block as if it were angularity. A title-block angle tolerance is a plus or minus on the angle itself, while angularity is a zone width in length units. Also check that the angle is a basic dimension, shown boxed, and not a toleranced one.

Does Angularity need a datum?
Yes. Angularity relates the feature to a datum, so at least one datum reference is needed.
Which group of controls is Angularity in?
It is a Orientation control. The groups are form, profile, orientation, location and runout, and they differ in what they relate the feature to.
How do you measure Angularity?
One common method is the Sine bar and dial indicator: Part set at the basic angle on the bar, indicator across the surface, and the inspector records: Indicator range. The method table on this page lists the alternatives and what each records.
What is Angularity commonly confused with?
Perpendicularity. Angularity is for any angle other than 90 degrees; perpendicularity is the 90 degree case.
How do I enter Angularity in an inspection report?
Press GD&T on the row in the characteristic table, pick the symbol, type the tolerance and any modifier or datums. The tool writes the frame into the Requirement column as text, and the report prints it.

Open a drawing — free

Related

Do not scale drawingThird-angle projectionSheet 1 of 1balloonmydrawing.com
Built and supported by Paul: [email protected]. AS9102 is a standard of SAE International; this site is not affiliated with or endorsed by SAE. Nothing here reproduces the standard. Explanations are our own and are not legal or compliance advice.Privacy · Terms · Refunds