Angularity in GD&T
What Angularity controls
Angularity controls orientation at an angle other than ninety degrees. The feature must stay within a zone that is tilted at the basic angle shown on the drawing relative to a datum. It controls tilt and also form of the surface, but not where the feature sits.
Tolerance zone. For a surface, the zone is the space between two parallel planes a tolerance value apart, set at the basic angle to the datum. For an axis with a diameter sign it is a cylinder at that angle.
How Angularity is inspected
On a surface plate, rest the datum surface on a sine bar or an adjustable angle block set to the basic angle, then sweep an indicator over the feature and read the spread. A coordinate measuring machine measures the feature and the datum and reports the angle error converted to the zone width.
How to measure Angularity
Angularity is measured with the instruments below; the table says how each is set up and what you write down.
| Instrument | Set-up | What is recorded |
|---|---|---|
| Sine bar and dial indicator | Part set at the basic angle on the bar, indicator across the surface | Indicator range |
| CMM | Points on the surface and on the datum, angle derived | Zone width the surface occupies |
Angularity compared with Perpendicularity
| Commonly confused with | The difference |
|---|---|
| Perpendicularity | Angularity is for any angle other than 90 degrees; perpendicularity is the 90 degree case. |
How to enter Angularity in the tool
In the characteristic table, press GD&T on the row, choose the Angularity symbol, type the tolerance and choose the datum letters in the order the frame prints them. The tool writes the frame into the Requirement column as text, and the report prints it. For example, a frame with a tolerance of 0.1 is written as ∠ | 0.1 | A on screen and as ANG | 0.1 | A in the PDF report, where the standard PDF fonts have no GD&T glyphs.
Datum reference: Yes. Angularity relates the feature to a datum, so at least one datum reference is needed.
Worked example: reading and judging a Angularity frame
The bundled sample drawing has no feature control frames, so this example uses an invented frame, written by the tool as ∠ | 0.1 | A. The tolerance is 0.1, which gives a zone 0.1 wide. The inspector measures the feature and finds a Angularity error of 0.08. That is less than 0.1, so the feature is in tolerance with room to spare. A second part measures 0.12. That is more than 0.1, so it is out of tolerance by 0.02. The report row for the second part carries the frame text as the requirement, 0.12 as the result, a verdict in words and a note saying what happened to the part.
| Measured Angularity | Tolerance | Verdict |
|---|---|---|
| 0.08 | 0.1 | In tolerance |
| 0.12 | 0.1 | Out of tolerance |
The numbers are generated from the example the tool itself uses for this symbol, so they stay in step with the frame text shown above. Both are illustrations, not data from a real part.
Mistakes to avoid with Angularity
Reading a general angular tolerance in the title block as if it were angularity. A title-block angle tolerance is a plus or minus on the angle itself, while angularity is a zone width in length units. Also check that the angle is a basic dimension, shown boxed, and not a toleranced one.
- Does Angularity need a datum?
- Yes. Angularity relates the feature to a datum, so at least one datum reference is needed.
- Which group of controls is Angularity in?
- It is a Orientation control. The groups are form, profile, orientation, location and runout, and they differ in what they relate the feature to.
- How do you measure Angularity?
- One common method is the Sine bar and dial indicator: Part set at the basic angle on the bar, indicator across the surface, and the inspector records: Indicator range. The method table on this page lists the alternatives and what each records.
- What is Angularity commonly confused with?
- Perpendicularity. Angularity is for any angle other than 90 degrees; perpendicularity is the 90 degree case.
- How do I enter Angularity in an inspection report?
- Press GD&T on the row in the characteristic table, pick the symbol, type the tolerance and any modifier or datums. The tool writes the frame into the Requirement column as text, and the report prints it.