Parallelism in GD&T
What Parallelism controls
Parallelism controls how nearly a feature runs parallel to a datum. It is an orientation control. It limits tilt and also the flatness of a surface, so a bowed face can fail parallelism even when its two ends are level with the datum.
Tolerance zone. For a surface the zone is two parallel planes a tolerance value apart, parallel to the datum. For an axis with a diameter sign the zone is a cylinder parallel to the datum axis.
How Parallelism is inspected
Seat the datum feature on a surface plate and sweep an indicator over the controlled surface; the full indicator reading across the surface is the parallelism error. For two bores, a pin gauge in each with an indicator across them shows how far the axes depart. A coordinate measuring machine reports it directly after establishing the datum.
How to measure Parallelism
Parallelism is measured with the instruments below; the table says how each is set up and what you write down.
| Instrument | Set-up | What is recorded |
|---|---|---|
| Dial indicator on a plate | Datum face on the plate, indicator swept across the controlled surface | Indicator range |
| CMM | Datum plane built, points on the feature | Zone width the feature occupies |
Parallelism compared with Flatness
| Commonly confused with | The difference |
|---|---|
| Flatness | Parallelism is measured from a datum; flatness is not. |
How to enter Parallelism in the tool
In the characteristic table, press GD&T on the row, choose the Parallelism symbol, type the tolerance and choose the datum letters in the order the frame prints them. The tool writes the frame into the Requirement column as text, and the report prints it. For example, a frame with a tolerance of 0.05 is written as ∥ | 0.05 | A on screen and as PARA | 0.05 | A in the PDF report, where the standard PDF fonts have no GD&T glyphs.
Datum reference: Yes. Parallelism is relative to a datum, so a datum reference is required.
Worked example: reading and judging a Parallelism frame
The bundled sample drawing has no feature control frames, so this example uses an invented frame, written by the tool as ∥ | 0.05 | A. The tolerance is 0.05, which gives a zone 0.05 wide. The inspector measures the feature and finds a Parallelism error of 0.040. That is less than 0.05, so the feature is in tolerance with room to spare. A second part measures 0.060. That is more than 0.05, so it is out of tolerance by 0.010. The report row for the second part carries the frame text as the requirement, 0.060 as the result, a verdict in words and a note saying what happened to the part.
| Measured Parallelism | Tolerance | Verdict |
|---|---|---|
| 0.040 | 0.05 | In tolerance |
| 0.060 | 0.05 | Out of tolerance |
The numbers are generated from the example the tool itself uses for this symbol, so they stay in step with the frame text shown above. Both are illustrations, not data from a real part.
Mistakes to avoid with Parallelism
Measuring thickness with a micrometer at a few points and calling it parallelism. A micrometer finds size variation between points, not the plane relationship. Also check that the datum is clean and seated; a chip under the datum surface shows up as a false parallelism error.
- Does Parallelism need a datum?
- Yes. Parallelism is relative to a datum, so a datum reference is required.
- Which group of controls is Parallelism in?
- It is a Orientation control. The groups are form, profile, orientation, location and runout, and they differ in what they relate the feature to.
- How do you measure Parallelism?
- One common method is the Dial indicator on a plate: Datum face on the plate, indicator swept across the controlled surface, and the inspector records: Indicator range. The method table on this page lists the alternatives and what each records.
- What is Parallelism commonly confused with?
- Flatness. Parallelism is measured from a datum; flatness is not.
- How do I enter Parallelism in an inspection report?
- Press GD&T on the row in the characteristic table, pick the symbol, type the tolerance and any modifier or datums. The tool writes the frame into the Requirement column as text, and the report prints it.