Flatness limits how far a surface may deviate from a plane, regardless of any other feature.

Detail A · What it controls

What Flatness controls

Flatness is a form control for one surface. Every point on the surface must lie between two parallel planes a tolerance value apart. It does not care about the angle of those planes or where they sit, only that the surface fits between them, so there is no datum.

Tolerance zone. The zone is the slab between two parallel planes. The planes can tilt to wherever they best contain the surface, which is why a flatness check is independent of how the part is clamped.

Detail B · How an inspector checks it

How Flatness is inspected

Place the part on a surface plate on three supports, then sweep a dial indicator across the surface and read the spread, or use a height gauge. A coordinate measuring machine measures a grid of points and reports the distance between the two best-fit planes that enclose them. Take points across the whole surface, not only along the edges, or you will miss a bow in the middle.

How to measure Flatness

Flatness is measured with the instruments below; the table says how each is set up and what you write down.

Instrument Set-up What is recorded
Surface plate with height gauge or dial indicator Part on three supports, indicator swept over the surface Total indicator range across the surface
CMM Many points taken over the surface, a plane is fitted Spread of the points about the fitted plane
Optical flat or flatness gauge Part placed on the flat, fringes read Fringe count converted to height

Flatness compared with Parallelism

Commonly confused with The difference
Parallelism Flatness has no datum; parallelism measures against a datum plane and also controls flatness within its zone.
Detail C · Entering it in the tool

How to enter Flatness in the tool

In the characteristic table, press GD&T on the row, choose the Flatness symbol, type the tolerance. The tool writes the frame into the Requirement column as text, and the report prints it. For example, a frame with a tolerance of 0.1 is written as ⏥ | 0.1 on screen and as FLAT | 0.1 in the PDF report, where the standard PDF fonts have no GD&T glyphs.

Datum reference: No. Flatness is a form tolerance and takes no datum reference.

Worked example: reading and judging a Flatness frame

The bundled sample drawing has no feature control frames, so this example uses an invented frame, written by the tool as ⏥ | 0.1. The tolerance is 0.1, which gives a zone 0.1 wide. The inspector measures the feature and finds a Flatness error of 0.08. That is less than 0.1, so the feature is in tolerance with room to spare. A second part measures 0.12. That is more than 0.1, so it is out of tolerance by 0.02. The report row for the second part carries the frame text as the requirement, 0.12 as the result, a verdict in words and a note saying what happened to the part.

Measured Flatness Tolerance Verdict
0.08 0.1 In tolerance
0.12 0.1 Out of tolerance

The numbers are generated from the example the tool itself uses for this symbol, so they stay in step with the frame text shown above. Both are illustrations, not data from a real part.

Detail D · Common mistakes

Mistakes to avoid with Flatness

Flatness is not thickness. A plate can be perfectly flat and the wrong thickness, or the right thickness and bowed. Do not confuse it with parallelism, which relates the surface to a datum. Also avoid pulling the part flat in a vice before measuring, since that hides the error you are meant to find.

Does Flatness need a datum?
No. Flatness is a form tolerance and takes no datum reference.
Which group of controls is Flatness in?
It is a Form control. The groups are form, profile, orientation, location and runout, and they differ in what they relate the feature to.
How do you measure Flatness?
One common method is the Surface plate with height gauge or dial indicator: Part on three supports, indicator swept over the surface, and the inspector records: Total indicator range across the surface. The method table on this page lists the alternatives and what each records.
What is Flatness commonly confused with?
Parallelism. Flatness has no datum; parallelism measures against a datum plane and also controls flatness within its zone.
How do I enter Flatness in an inspection report?
Press GD&T on the row in the characteristic table, pick the symbol, type the tolerance and any modifier or datums. The tool writes the frame into the Requirement column as text, and the report prints it.