Concentricity in GD&T

Last reviewed 19 November 2026 · Written by Paul, who also builds and supports the tool

Concentricity limits how far the median points of a feature may stray from a datum axis.

Detail A · What it controls

What Concentricity controls

Concentricity controls whether the centre of a round feature lies on a datum axis, judged from the median points of its cross-sections rather than from its outer surface. Because it needs those median points, it asks for far more measurement than most other controls.

Tolerance zone. The zone is a cylinder around the datum axis. Every median point of the feature must lie inside it, so you need many cross-section points to judge it.

Detail B · How an inspector checks it

How Concentricity is inspected

You need a coordinate measuring machine or a roundness tester that can pick up many cross-sections, find the centre of each and compare them with the datum axis. Dial-indicator methods do not give median points, so a rotating indicator reading is a runout check, not a concentricity check.

How to measure Concentricity

Concentricity is measured with the instruments below; the table says how each is set up and what you write down.

Instrument Set-up What is recorded
CMM Median points of the feature derived from cross-sections Offset of the derived axis from the datum axis, doubled
Roundness tester Datum axis fixed, trace taken of the feature Offset of the trace centre

Concentricity compared with Circular runout

Commonly confused with The difference
Circular runout Runout is a surface measurement with a dial indicator; concentricity needs derived median points.
Detail C · Entering it in the tool

How to enter Concentricity in the tool

In the characteristic table, press GD&T on the row, choose the Concentricity symbol, type the tolerance, tick Diameter zone and choose the datum letters in the order the frame prints them. The tool writes the frame into the Requirement column as text, and the report prints it. For example, a frame with a tolerance of 0.1 is written as ◎ | Ø0.1 | A on screen and as CONC | Ø0.1 | A in the PDF report, where the standard PDF fonts have no GD&T glyphs.

Datum reference: Yes. It always refers to a datum axis.

Worked example: reading and judging a Concentricity frame

The bundled sample drawing has no feature control frames, so this example uses an invented frame, written by the tool as ◎ | Ø0.1 | A. The tolerance is 0.1, which gives a cylindrical zone 0.1 across. The inspector measures the feature and finds a Concentricity error of 0.08. That is less than 0.1, so the feature is in tolerance with room to spare. A second part measures 0.12. That is more than 0.1, so it is out of tolerance by 0.02. The report row for the second part carries the frame text as the requirement, 0.12 as the result, a verdict in words and a note saying what happened to the part.

Measured Concentricity Tolerance Verdict
0.08 0.1 In tolerance
0.12 0.1 Out of tolerance

The numbers are generated from the example the tool itself uses for this symbol, so they stay in step with the frame text shown above. Both are illustrations, not data from a real part.

Detail D · Common mistakes

Mistakes to avoid with Concentricity

Specifying it where runout or position would do. Many shops ask for runout or position instead, because those controls are cheaper to measure and usually serve the same function. If a drawing does call concentricity, do not substitute runout results in the report: say what you measured.

Does Concentricity need a datum?
Yes. It always refers to a datum axis.
Which group of controls is Concentricity in?
It is a Location control. The groups are form, profile, orientation, location and runout, and they differ in what they relate the feature to.
How do you measure Concentricity?
One common method is the CMM: Median points of the feature derived from cross-sections, and the inspector records: Offset of the derived axis from the datum axis, doubled. The method table on this page lists the alternatives and what each records.
What is Concentricity commonly confused with?
Circular runout. Runout is a surface measurement with a dial indicator; concentricity needs derived median points.
How do I enter Concentricity in an inspection report?
Press GD&T on the row in the characteristic table, pick the symbol, type the tolerance and any modifier or datums. The tool writes the frame into the Requirement column as text, and the report prints it.